A
ADSS
All-dielectric self-supporting (ADSS) cable hangs between poles with no steel messenger or bond wire. Aramid yarn carries tension while the jacket resists sun and electrical tracking. With no metal inside, it can ride in the communications space near power without grounding.
Lines owned by Eversource and the Electric Co-op often accept ADSS to limit added steel and bonding work.
As-Builts
As-builts record the plant as built, with GPS vaults, pole ties, depths, counts, splice spots, and field changes. They include KMZ/DWG/PDF maps, fiber assignments, and .sor OTDR (optical time-domain reflectometer) files with PDF summaries. Owners use them to find cable, avoid dig-ins, and close grants.
Towns from Derry to Dover accept GIS as-builts that drop directly into public-works mapping systems.
B
Backhaul
Backhaul is middle-mile glass that hauls combined traffic from towers, schools, and business parks to core gateways. It needs capacity, diverse routing, and low delay to carry 5G and cloud loads. Carriers replace microwave and copper with this fiber when growth demands it.
Upgrades along I-89 and I-93 tie northern towers back to Manchester huts for denser 5G coverage.
BEAD
Broadband Equity, Access, and Deployment (BEAD) is the federal grant effort run through states to reach unserved places. States score areas and enforce wage, sourcing, and performance terms. Contractors help with maps, estimates, builds, Tier 1/Tier 2 tests, and closeout files.
The New Hampshire broadband office at Business and Economic Affairs guides applicants through local BEAD steps.
D
Dark Fiber
Dark fiber is spare unlit glass leased without electronics so the tenant supplies its own lasers. Hospitals, campuses, and carriers use it for private low-latency paths they control. Contracts list counts, route miles, hut access, and repair windows.
Business parks between Manchester and Nashua lease dark strands for diverse links to Seacoast clinics.
F
FTTH / PON
FTTH (fiber to the home) runs glass to each premise; passive optical network (PON) is the shared design that feeds it. One port splits to 32 or 64 homes through passive splitters needing no field power. A 1x32 link often tests 15-28 dB all in.
Rural builds in Grafton and Coos counties use passive optical network (PON) to stretch one hut across long drop distances.
Fusion Splice
A fusion splice aligns two fiber ends and melts the glass with an electric arc for a permanent low-loss joint. Core-alignment machines average 0.02-0.05 dB, well under the 0.10-dB target and 0.3-dB TIA-568.3-D maximum. Sleeves meeting Telcordia GR-765 protect the bare section.
Heated trailers keep splicers accurate during Franconia Notch winter work when arcs drift in cold wind.
H
Handhole / Vault
A handhole is a small box for slack, bends, and test access with a lift-off lid. A vault is a larger precast room, often H-20 rated, for racking cable and mounting closures. Both break long duct runs into safe pulling and repair points.
Polymer boxes and drainable vaults along Route 101 resist plow strikes and seasonal high groundwater.
HDD (Horizontal Directional Drilling)
HDD (horizontal directional drilling) bores a curved pilot hole, reams it larger, then pulls back duct without open trenching. It slips under roads, rivers, and ledge with small entry and exit pits. Crews track depth, control mud, and restore ground to permit terms.
Granite till around Concord and the Merrimack River often forces HDD instead of open trench digging.
I
Innerduct / Microduct
Innerduct divides large duct with smaller smooth tubes that shield cable during long pulls. Microduct is a 10- to 16-mm version made for blowing microcable on air. Both cut friction, add spare paths, and use color to mark owners or services.
Campuses in Durham and Hanover blow new microcable through spare microduct instead of retrenching quads.
L
Loss Budget
A loss budget adds fiber attenuation plus allowances for splices, connector pairs, splitters, and margin to set the pass limit. A 10-km OS2 link at 0.4 dB/km with four 0.10-dB splices allows about 5.9 dB with connectors. Tier 1 loss must test under that value.
Designers add winter margin on North Country spans near Berlin where cold stiffens jackets and tightens bends.
M
Make-Ready and One-Touch Make-Ready
Make-ready prepares poles for a new attachment by moving lines, swapping short poles, or raising height for clearance. One-touch make-ready lets one approved crew shift simple communications attachments in a single visit. Both follow National Electrical Safety Code (NESC) spacing before any fiber is hung.
Eversource, Consolidated, and NHEC coordinate make-ready under New Hampshire utility pole rules for most town roads.
Mechanical Splice
A mechanical splice holds two cleaved fibers in a precision V-groove with index-matching gel and a clamp. It typically adds 0.10-0.30 dB and installs in minutes without power or arc. Crews use it for fast temporary relights, then replace it with a fusion splice.
Storm trucks on the Seacoast carry mechanical kits to relight cut drops until fusion crews arrive.
Microtrenching
Microtrenching saws a 1- to 2-inch slot about 12 to 18 inches deep, sets microduct, then seals it with grout. It places downtown fiber fast with small traffic control. Depth control, clean base rock, verified clearances, and city approval decide where it holds.
Freeze-thaw and plows limit microtrench use, so agencies review each downtown block on its own merits.
MPO / MTP
An MPO (multi-fiber push-on) connector joins 12 or 24 fibers in one ferrule; MTP is a variant. It feeds dense trunks and 40/100-gig links, including 400GBASE-DR4 on eight fibers of MPO-12. Single-mode ends meeting Telcordia GR-326 still need correct polarity, pinning, and cleaning to pass.
Edge suites in Manchester use multi-fiber push-on (MPO) trunks for fast replication links that demand strict polarity control.
Multimode Fiber (OM3/OM4/OM5)
Multimode fiber uses a 50-micron core and low-cost VCSEL (vertical-cavity surface-emitting laser) sources at 850/1300 nm. OM3, OM4, and OM5 support 10- to 100-gigabit links from 100 to 550 meters, with OM5 enabling shortwave multiplexing. Use stays inside buildings and data rooms.
University labs in Durham and Hanover choose OM4 for short 40-gig links between server rows.
O
OLTS
An optical loss test set (OLTS) pairs a calibrated source and power meter to read insertion loss, length, and polarity. Single-mode links use 1310/1550 nm; multimode links use 850/1300 nm per TIA-526-7-A and TIA-526-14-C respectively. It supplies the Tier 1 result owners need for acceptance.
Hospitals in Concord and Manchester require OLTS files at closeout before clinical networks carry live traffic.
OTDR
An optical time-domain reflectometer (OTDR) sends short light pulses and plots reflections by distance to locate splices, connectors, bends, and breaks. It reports event loss, reflectance, and total length. Its two-way trace supports Tier 2 records alongside Tier 1 loss tests.
Crews run winter OTDR checks on New Hampshire White Mountains routes where ice shifts aerial plant and opens microbends.
Overlash
Overlash straps new optical cable to an existing strand or cable with a lasher and steel wire. It avoids new poles while speeding builds along proven routes. Engineers must still check pole loading for wind plus ice and secure owner approval before lashing.
Village routes around Keene and the Lakes Region favor overlash where poles already hold several attachments.
P
Pole Attachment
A pole attachment grants licensed space to hang fiber, strand, or hardware on a utility pole. It needs an application, survey, National Electrical Safety Code (NESC) load and clearance check, signed agreement, and yearly rent. Installers must hold road clearances and power separation after construction.
Most New Hampshire poles belong to Eversource, Consolidated, NHEC, or Unitil under active commission oversight.
R
Ribbon Fiber
Ribbon fiber bonds 12 fibers in flat strips that a mass fusion splicer joins in one arc. A 144-count cable needs only 12 burns instead of 144 singles, which speeds backbone work. Ribbons need flat routing to avoid preferential bends and edge separation.
Middle-mile routes through Merrimack Valley often specify ribbon cable to shorten busy highway closure windows.
S
Single-Mode Fiber
Single-mode fiber uses a 9-micron core that guides one light path for tens of kilometers at very low loss. It runs on laser light at 1310/1550 nm and feeds PON (passive optical network) and long-haul Ethernet. Most outside-plant cable is bend-insensitive G.652.D or G.657.A2 single-mode (OS2).
Ice-prone aerial spans in New Hampshire Coos County favor G.657 bend-insensitive glass that tolerates tighter winter bends.
Splice Closure
A splice closure is a sealed dome or inline case that holds trays, sleeves, and splitters away from water and strain. It meets Telcordia GR-771 for sealing, cable retention, and re-entry. Mounting height, drip loops, and slack routing decide whether it survives storms.
Valley crews hang closures above spring flood marks along the Connecticut River to avoid ice-jam soaking.
T
Tier 1 / Tier 2 Certification
Tier 1 certification tests each link with an optical loss test set (OLTS) for insertion loss, length, and polarity against TIA-568.3-D limits. Single-mode follows TIA-526-7-A; multimode follows TIA-526-14-C. Tier 2 adds bidirectional optical time-domain reflectometer (OTDR) traces to show every splice and connector event.
Broadband grant builds around Durham and Hanover usually specify Tier 1 plus two-way Tier 2 records for payment.
Keep reading
Guides that put these terms to work

Fiber Optic Installation Cost per Foot in New Hampshire: What Drives the Price
Fiber optic installation cost per foot in New Hampshire spans a few dollars indoors to $40-plus underground where ledge and pavement control labor. Reviewed by our BICSI Registered Communications Distribution Designer (RCDD), outside-plant manager for methods and pricing logic.

OTDR Testing Explained for New Hampshire: Traces, Loss Budgets and Tier 2 Certification
Optical time-domain reflectometer (OTDR) testing locates faults by distance, while optical loss test set (OLTS) certification proves total loss passes budget. Reviewed by our FOA CFOS/T, senior field supervisor, November 2026 insight from hospital and campus builds.

Fusion Splicing vs Mechanical Splicing: How Fiber Splicing Works in New Hampshire
Fusion splicing melts two glass fibers into one joint at 0.02 to 0.05 decibels. Mechanical splicing clamps them at 0.20 to 0.50 decibels. Reviewed by our FOA CFOS/T, senior fiber project manager.

Start a project
Get a Fixed Fiber Price
Send drawings or route Google Earth map file (KMZ). Get itemized price, schedule window and exclusions within one business day.
Expect a planning estimate within one business day.