NH Contractor License #NH-889348 · Bonded & insuredAll 10 counties
Fiber Optics New Hampshire

Guide · 8 min read

FTTH Network Architecture in New Hampshire: PON, FDH and MST Explained

PON splitters, FDH cabinets and multiport service terminal (MST) terminals decide FTTH cost and performance. This guide explains ftth network architecture choices for New Hampshire builds with clear numbers and field notes.

Reviewed by the New Hampshire engineering teamUpdated 2026
Macro view of ribbon fiber strands

Quick answer

FTTH network architecture is usually passive optical network (PON): one OLT port feeds a splitter that serves 32 homes. An FDH cabinet holds splitters, MST terminals split drops near homes, and GPON or XGS-PON sets speed and light budget.

Good ftth network architecture keeps split ratios, light levels and splice points simple from office to home. Our FTTH build crew plans PON layouts with 1:32 splits, FDH hubs and MST taps. They fit New Hampshire pole lines and village roads.

You will see how GPON and XGS-PON differ, where FDH cabinets belong, and how drops reach houses through granite and ice country. Numbers cover loss budgets, test limits, and closeout files so bids compare on facts.

01

What Is a PON Network and How Does It Share One Fiber?

A PON network uses a single feeder fiber to serve many homes through passive splitters. An OLT (optical line terminal) in the central office sends downstream light to a splitter. Each optical network terminal (ONT) at the home receives its share and sends upstream bursts on a timed schedule. No powered electronics sit between office and home.

Design starts at the serving area boundary and works back to the office. Engineers set a 1:32 split for most subdivisions and 1:64 where takeoff density is high. Feeder counts run 48 to 144 strands, while distribution runs 12 to 48 strands. Our engineered outside-plant drawings show splice points, splitter ports and measured distances before crews place cable.

02

GPON vs XGS-PON: Which Split and Speed Fit Your Plan?

GPON (Gigabit-capable Passive Optical Network) delivers 2.5 Gbps down and 1.25 Gbps up per PON port under ITU-T G.984. XGS-PON (10-Gigabit Symmetrical Passive Optical Network) delivers 10 Gbps down and 10 Gbps up per port under ITU-T G.9807. Both use different wavelengths for downstream and upstream so one fiber carries both directions. XGS-PON optics need tighter loss control and cleaner connectors.

Light budget decides the winner for each serving area. GPON allows about 28 dB end-to-end loss with Class B+ optics. XGS-PON allows about 29 dB with N1 optics or 31 dB with N2 optics. A sample path uses 8 km of single-mode (OS2) at 0.4 dB per km. Four fusion splices at 0.05 dB each and four mated pairs at 0.3 dB each totals 4.6 dB. Either system passes, but XGS-PON leaves room for higher splits or longer reach.

03

What Is an FDH Cabinet and Where Does It Sit?

An FDH (fiber distribution hub) is the cross-connect cabinet between feeder and distribution. Feeder fibers land on one side, splitter inputs and parking positions sit inside, and distribution fibers leave to MST terminals. Cabinets range from 144 to 432 ports and use angled SC or hardened MPO inputs. Good labeling follows TIA-606-C with unique fiber and port IDs.

Manchester and Nashua subdivisions often place one FDH for 200 to 300 passing homes near a road intersection. Portsmouth and Dover crews mount smaller hubs on short side streets to shorten drop lengths. Field supervisor Dawn Hartman (FOA CFOS/S) sets pad height above plow splash and grades conduit entries for drainage. Cabinets get bonded per TIA-607-D and grounded to resist lightning on exposed ridges.

04

FTTH vs FTTP vs FTTx: What Do the Terms Mean for Bids?

Bids mix FTTH, FTTP and FTTx because vendors define the endpoint differently. FTTH means fiber ends inside the home at an ONT. FTTP means fiber ends at the premises, which can be a home or a small business. FTTx is the family term that also covers curb, building and node designs where copper or coax finishes the run.

For New Hampshire bid review, ask for the exact handoff drawing and test point. A true FTTH scope shows ONT location, drop count and Tier 1 plus OTDR proof. Our recent 1,840-passing build near Concord used 1:32 splitters, 288-count feeder and 96 MST ports. Closeout arrived in five business days with .sor optical time-domain reflectometer (OTDR) files, PDF reports and Google Earth map file (KMZ) as-builts. Review choosing aerial or buried routes before you lock the endpoint definition.

05

How Is Fiber Run to a House on Granite, Ice and Mud?

Drops leave the MST terminal and follow the shortest maintainable path to the house. Aerial drops use flat or figure-8 cable lashed to a messenger or self-supporting ADSS (All-Dielectric Self-Supporting) cable where poles allow. Buried drops use 1-inch conduit or direct-buried flat drop at 18 to 24 inches where soils permit. National Electrical Safety Code (NESC) clearances and NHDOT permits control road crossings and pole attachments.

Granite ledge around Laconia, Keene and the White Mountain foothills forces shallow rock cuts or short bores. Spring mud season in Franklin and Claremont softens shoulders, so mats and tracked equipment protect lawns. Winter ice loading adds sag and galloping risk on long spans near Lebanon and Berlin. Compare bore, trench and microtrench options for driveways and ledge, and plan snow stakes so drops stay visible to plows.

06

How Do You Test and Document a PON Build for Acceptance?

Acceptance needs Tier 1 plus OTDR proof on every distribution path. Tier 1 uses an optical loss test set (OLTS) for insertion loss, length and polarity. It tests at 1310/1550 nm for OS2 and 850/1300 nm for multimode. Tier 2 adds the OTDR trace to find bends, bad splices and reflectance events. Targets are fusion splice at or below 0.10 dB average and mated pair at or below 0.75 dB maximum. OS2 cable runs at or below 0.4 dB per km at 1310 nm.

Closeout ties every result to a fiber ID for regional ISPs and carriers that need audit-ready records. You receive OLTS tables, .sor files, splitter and MST maps, and splice assignments in PDF and KMZ. Registered Communications Distribution Designer (RCDD) reviewer Paige Zamora checks labeling, grounding and loss math before sign-off. A workmanship warranty of 2 years backs installed plant work. If you have addresses or a route sketch, send them for a layout review and split plan.

GPON vs XGS-PON for FTTH builds
FeatureGPONXGS-PON
Capacity per PON port2.5 Gbps down / 1.25 Gbps up10 Gbps down / 10 Gbps up
StandardITU-T G.984ITU-T G.9807
Typical split1:32, up to 1:641:32, up to 1:64 with N2 optics
Loss allowanceAbout 28 dB Class B+About 29 dB N1, 31 dB N2
Best fitResidential subdivisions on budgetCampuses, business areas, future 10G

Key takeaways

  • One OLT port usually serves 32 homes through a passive splitter.
  • FDH cabinets join feeder to distribution; MST terminals shorten drops.
  • GPON fits homes now; XGS-PON adds symmetrical 10G headroom.
  • Tier 1 plus OTDR proof with maps closes a PON build cleanly.

FAQ

Related questions

Explains port splits, shared fiber generations, cabinet placement and acceptance tests.

How many homes can one PON port serve?

Most designs use a 1:32 split, so one port serves 32 homes or small businesses. Dense areas can use 1:64 if the loss budget allows. Higher splits reduce feeder fiber but raise splitter loss by about 3 dB per doubling. Check distance, splices and connectors before approving 1:64.

Do GPON and XGS-PON run on the same fiber?

Yes, both run on OS2 single-mode fiber and share splitter plant in many designs. They use different wavelengths, so they can coexist with proper filters. XGS-PON needs cleaner connectors and tighter loss control. Plan spare ports and document wavelengths to allow migration without rebuilding drops.

Where should the FDH cabinet go?

Place the FDH near the center of 200 to 300 passings to shorten distribution runs. Keep it above plow splash, near power for future use, and clear of wetlands. Confirm pad access for splice vans and snow removal. Good placement cuts drop length, splice time and winter maintenance trips.

What tests prove a new FTTH area is ready?

Require Tier 1 insertion-loss tests plus OTDR traces on feeder and distribution. Accept fusion splices at or below 0.10 dB and mated pairs at or below 0.75 dB. Deliver OLTS tables, .sor files, splitter maps and as-builts. Review failures for bends or dirty connectors before customer turn-up.

Keep reading

Related guides

10 min read

BEAD Program New Hampshire: Broadband Funding, Match Rules and Fiber Build Deadlines

Broadband Equity, Access, and Deployment (BEAD) money in New Hampshire goes to providers as subgrants, not directly to contractors. Awards reward low cost per served location. Reviewed by our BICSI RCDD, Senior Outside-Plant Designer.

9 min read

OSP Fiber Design in New Hampshire: HLD vs LLD Fiber Design Deliverables

You learn the difference between HLD and LLD for outside plant (OSP) fiber. It shows what drawings and splice records to demand. New Hampshire permits and pole reviews shape budget and schedule.

9 min read

Pre-Terminated Fiber vs Field Termination in New Hampshire: MPO/MTP Trunks vs Field Splicing

Compare pre-terminated MPO trunks and field splicing for data halls and campuses. Learn cost, loss, polarity, and testing tradeoffs, plus when each method fits New Hampshire buildings and ground conditions.

Schedule a site visit

Book a Route Walk-Out

Share addresses and access notes. Receive field-verified route, photos and budget with dates within two business days.

Dig Safe 811 locates and roadway checks ride along.

24/7 dispatch & restoration(603) 555-1131Use (603) 555-1131 24/7 and get a reply when fiber goes dark. Crews based in Nashua, Manchester and Portsmouth lay temporary cable to get circuits up, then splice the permanent repair and test it again.